The provided RPG program, BB705P.rpg36.txt, is written for the IBM System/36 and is called by the OCL program BB705P.ocl36.txt previously discussed. This RPG program generates a Pending Order Listing based on parameters such as location, container, date, and carrier. Below, I’ll explain the process steps, business rules, tables used, and any external programs called.

Process Steps of the RPG Program

The RPG program processes user input from a workstation screen, validates parameters, and prepares data for generating an open order listing. Here’s a step-by-step breakdown of the process:

  1. File and Data Definitions:
  2. Files:
    • SCREEN: A workstation file (display file) for user interaction, with a record format SCREEN used to prompt for input parameters.
    • INLOC: A disk file (512 bytes, indexed, shared read mode) containing location data.
    • BICONT: A disk file (256 bytes, indexed, shared read mode) containing company or container data.
  3. Data Structures:
    • COM: A table (array) with 5 elements, each 40 characters, used to store error messages (defined in the ** COM section at the end).
    • UDS: User Data Structure for holding input parameters like KYCO (company), KYLOC (location), KYFRDT (from date), KYTODT (to date), KYZEYN (zero date flag), KYJOBQ (job queue flag), KYCOPY (number of copies), FRDT8 (8-digit from date), TODT8 (8-digit to date), Y2KCEN (century for Y2K), and Y2KCMP (comparison year for Y2K).
  4. Screen Input Fields (record format SCREEN, NS 01):
    • KYCO (company, positions 3-4)
    • KYLOC (location, positions 5-7)
    • KYFRDT (from date, positions 8-13)
    • KYTODT (to date, positions 14-19)
    • KYZEYN (zero date flag, position 20)
    • KYJOBQ (job queue flag, position 21)
    • KYCOPY (number of copies, positions 22-23)
  5. File Input Fields:

    • INLOC: Fields like ILDEL (delete flag), ILCONO (company), ILLOC (location), ILNAME (location name).
    • BICONT: Fields like BCDEL (delete flag).
  6. Initialization:

  7. Line 0040-0042: Set indicators 30, 31, 32, 33, 34, 81, 90, 99 to off to reset the program state.
  8. Line 0043: Initialize MSG (error message field) to blanks.
  9. Line 0045-0048: If indicator 09 is on (first cycle), execute the ONETIM subroutine to set default values and exit:

    • ONETIM (lines 0142-0152):
    • Sets KYCO to 10, KYLOC to '001', KYZEYN to 'N', KYJOBQ to 'N', KYCOPY to 1.
    • Sets indicator 81 to display the screen.
    • Exits to the END tag.
  10. Main Processing Logic:

  11. Line 0050-0054: If indicator KG (likely a cancel key) is on, set indicator U8 (cancel job), set LR (last record), and exit to END.
  12. Line 0055-0057: If indicator 01 is on (screen input received), execute the S1 subroutine and exit to END.

  13. S1 Subroutine (Validation Logic) (lines 0061-0140):

  14. Company Validation (lines 0063-0067):
    • Chain (lookup) BICONT using KYCO. If not found (30 on) or if BCDEL = 'D' (deleted record), set error message COM,1 ("INVALID COMPANY NUMBER ENTERED") and indicators 81, 90. Jump to ENDS1.
  15. Date Conversion for Y2K (lines 0069-0088):
    • Convert KYFRDT and KYTODT (6-digit dates, YYMMDD) to 8-digit formats (FRDT8, TODT8) by adding century:
    • Multiply dates by 10000.01 to shift format.
    • Extract year (FYY, TYY) and compare with Y2KCMP (comparison year, e.g., 80 for 1980).
    • If year ≥ Y2KCMP, use Y2KCEN (e.g., 19 for 1900s); else, add 1 to Y2KCEN (e.g., 20 for 2000s).
    • Construct FRDT8 and TODT8 (e.g., CCYYMMDD).
  16. Location Validation (lines 0090-0095):
    • Build INKEY from KYCO and KYLOC, then chain INLOC. If not found (99 on), set error message COM,3 ("INVALID LOCATION ENTERED") and indicators 81, 90, 32. Jump to ENDS1.
  17. Zero Date Validation (lines 0098-0113):
    • If KYZEYN = 'Y' (allow zero dates), check if FRDT or TODT is non-zero. If so, set error message COM,5 ("CANNOT ENTER DATE IF ZERO REQUEST = 'Y'") and indicators 81, 90, 31. Jump to ENDS1.
  18. Date Range Validation (lines 0115-0119):
    • If FRDT8 > TODT8, set error message COM,2 ("FROM DATE GREATER THAN TO DATE") and indicators 81, 90, 31. Jump to ENDS1.
  19. Parameter Validation (lines 0122-0135):
    • Check KYZEYN for valid values (' ', 'N', 'Y'). If invalid (33 on), set error message COM,4 ("INVALID PARAMETER ENTERED - ' ', N OR Y") and indicators 81, 90. Jump to ENDS1.
    • Check KYJOBQ for valid values (' ', 'N', 'Y'). If invalid (34 on), set error message COM,4 and indicators 81, 90. Jump to ENDS1.
  20. Copy Count Adjustment (lines 0136-0138):

    • If KYCOPY is zero, set it to 1 (default number of copies).
  21. Screen Output (lines 0155-0164):

  22. If indicator 81 is on, display the SCREEN file with:

    • Program name (BB705PFM in field K8).
    • Input fields (KYCO, KYLOC, KYFRDT, KYTODT, KYZEYN, KYJOBQ, KYCOPY).
    • Error message (MSG).
  23. Program Termination:

  24. The program ends at the END tag (line 0059) after processing or cancellation.
  25. If validation fails, it redisplays the screen with an error message. If validation passes, it likely prepares data for the BB705 program (called by the OCL).

Business Rules

The RPG program enforces the following business rules for generating the pending order listing:

  1. Company Validation:
  2. The company number (KYCO) must exist in the BICONT file and not be marked as deleted (BCDEL ≠ 'D').
  3. Invalid company triggers error message: "INVALID COMPANY NUMBER ENTERED".

  4. Location Validation:

  5. The location (KYLOC) combined with KYCO must exist in the INLOC file.
  6. Invalid location triggers error message: "INVALID LOCATION ENTERED".

  7. Date Range Validation:

  8. The from date (KYFRDT) must not be later than the to date (KYTODT) when converted to 8-digit format (FRDT8, TODT8).
  9. Invalid date range triggers error message: "FROM DATE GREATER THAN TO DATE".

  10. Zero Date Handling:

  11. If KYZEYN = 'Y' (allow zero dates), both KYFRDT and KYTODT must be zero. Non-zero dates trigger error message: "CANNOT ENTER DATE IF ZERO REQUEST = 'Y'".

  12. Parameter Validation:

  13. KYZEYN (zero date flag) must be ' ', 'N', or 'Y'.
  14. KYJOBQ (job queue flag) must be ' ', 'N', or 'Y'.
  15. Invalid values trigger error message: "INVALID PARAMETER ENTERED - ' ', N OR Y".

  16. Copy Count:

  17. If the number of copies (KYCOPY) is zero, it is set to 1 to ensure at least one copy of the report is generated.

  18. Y2K Date Handling:

  19. Dates are converted from 6-digit (YYMMDD) to 8-digit (CCYYMMDD) format using a century calculation based on Y2KCMP and Y2KCEN to handle dates before and after 2000 correctly.

Tables Used

  1. COM:
  2. Defined as an array (E specification, line 0007) with 5 elements, each 40 characters.
  3. Stores error messages listed at the end of the program:
    • COM,1: "INVALID COMPANY NUMBER ENTERED"
    • COM,2: "FROM DATE GREATER THAN TO DATE"
    • COM,3: "INVALID LOCATION ENTERED"
    • COM,4: "INVALID PARAMETER ENTERED - ' ', N OR Y"
    • COM,5: "CANNOT ENTER DATE IF ZERO REQUEST = 'Y'"
  4. Used to display error messages on the screen when validation fails.

  5. Files as Data Sources:

  6. INLOC: Contains location data (fields: ILDEL, ILCONO, ILLOC, ILNAME). Functions as a table for validating location and company combinations.
  7. BICONT: Contains company or container data (field: BCDEL). Functions as a table for validating company numbers.

No additional RPG tables (e.g., TABxxx) are defined explicitly in the program.

External Programs Called

  • BB705: Referenced in the screen output (line 0156, K8 'BB705PFM') and likely called by the OCL program after validation. The RPG program prepares input parameters for BB705, which generates the actual pending order listing.
  • Note: BB705PFM in the screen output suggests a display file or program name, but it aligns with the BB705 program called in the OCL (JOBQ ?CLIB?,BB705 or BB705 ,,,,,,,,?9?).

Summary

  • Process Steps:
  • Initialize indicators and clear error messages.
  • On first cycle (09), set default parameters via ONETIM and exit.
  • If cancel key (KG) is pressed, cancel the job and exit.
  • On screen input (01), validate parameters in the S1 subroutine:
    • Check company (BICONT), location (INLOC), date range, zero date flag, and parameter values.
    • Convert dates to 8-digit format for Y2K compliance.
    • Set default copy count if zero.
  • Display the screen with input fields and error messages if validation fails.
  • If validation passes, prepare parameters for the BB705 program called by the OCL.

  • Business Rules:

  • Validate company, location, date range, zero date flag, and parameter inputs.
  • Ensure Y2K-compliant date handling.
  • Default to one copy if none specified.
  • Display appropriate error messages for invalid inputs.

  • Tables Used:

  • COM: Array for error messages.
  • INLOC and BICONT: Files used as data tables for validation.

  • External Programs Called:

  • BB705: The program that generates the pending order listing, called by the OCL after validation.